The Wallgate NX electronic water controller is the brain of every concealed services electronic Wallgate installation. It manages flow, run-time, anti-flooding logic, anti-tamper logic and (where specified) hygiene flush schedules across one or more outlets – turning a Wallgate solid surface basin or toilet from a piece of fixed sanitaryware into a managed water-safety system.

The controller is referenced from every concealed services basin page in the Wallgate range and must be specified alongside the basin to deliver a working installation.

The Wallgate WDC200-NX 2 Rooms / 8 Outlets is suited to larger installations spanning multiple ensuites, adjacent bedrooms or treatment rooms with more than four outlets.


Why Specify

  • Run-time control – programmable activation duration per outlet, typical 8 to 30 seconds
  • Anti-flooding logic – automatic shutoff if a basin remains activated beyond programmed maximum
  • Anti-tamper logic – frequency limits to prevent vandalism via repeated activation
  • Hygiene flush – programmable scheduled flushes for line disinfection and water quality management
  • BMS-ready – outputs available for integration with building management systems
  • Per-outlet configuration – independent programming of each connected outlet
  • Bluetooth app control – programme and manage each controller remotely via the Wallgate app without access to the service void
  • Mains-powered – wall-mounted unit in service void
  • Required for all Wallgate concealed services electronic basin installations

Applications

Specified for every Wallgate concealed services electronic basin installation:

  • Mental health acute and forensic inpatient bedrooms
  • Custodial and corrections facilities – cells and observation rooms
  • Secure healthcare wards and behavioural assessment areas
  • NDIS SDA Robust bathrooms with concealed-services specification

Larger installations require multiple controllers – Galvin specification consultants can advise on configuration.


Hygiene Flush and Legionella Management

The NX programmable hygiene flush feature supports facility Water Safety Plans and Legionella risk management programs by automating scheduled flushes of low-use outlets – reducing the manual workload on facility engineers and producing an auditable record of flushing events. The hygiene flush schedule is configurable per outlet, allowing different schedules for clinical handwashing basins versus less-used outlets within the same facility. The NX provides the data layer that supports facility compliance with state health authority Water Safety Plan requirements; it does not replace the requirement for a documented Water Safety Plan.


Installation

  • The NX is wall-mounted in an accessible service void, mains-powered, with cabling out to solenoid valves at each connected basin (solenoid pack per outlet required, sold separately)
  • Programming is via the NX user interface or compatible programming tools – refer to the supplied installation and programming instructions.
  • Electrical installation by a licensed electrician; plumbing installation by a licensed plumber.
  • Specifiers should confirm service void access, electrical supply and BMS integration requirements early in the design process – these are not retrofittable without disturbance to the bathroom finishes.

Optional Extras

  • EXT400-1 Extension Cable Only, Stereo Jack Plug for Piezo & IR (4M)
  • EXTWV400 Valve Extension Cable with XLR Plug for Water Valve 4M
  • WVC400WC-4 Wallgate Cable for DF Kit to WDC Controller 4m Length
  • WVPB400-2-AUS Wallgate Electronic Activ Basin Valve Pack with H&C Outlets Complete with 2x 5LPM Solenoids 4M Cable
  • WVPB400-3-AUS Wallgate Electronic Activation Basin Valve Pack Single Outlet C/W 1x5LP Solenoid 4m Cable
  • DFKIT03-AUS Wallgate Electronic WC Direct Mains Flush Valve Assembly with Air Break Only
  • PBA050-2BA Wallgate Ligature Resistant Dual Basin Piezo Buttons with 4m Cable - Panelling (0-85mm Wall)
  • PBA051-1-CWC Wallgate Ligature Resistant Dual Flush Piezo Button WC with 4m Cables - Solid Wall (85-190mm Wall)
  • PBA050-1-CWC Wallgate Ligature Resistant Dual Flush Piezo Button with 4m Cable - Panelling (0-85mm Wall)
  • PBA051-SHWR Wallgate Ligature Resistant Single Shower Piezo Button 4m Cable - Solid Wall (85-190mm Wall)
  • PBA050-SHWR Wallgate Ligature Resistant Single Shower Piezo Button with 4m Cable - Panelling (0-85mm Wall)
  • PBA050-IR-SHWR Wallgate Single Infra-Red Shower Sensor with 4m Cable - Panelling (0-85mm Wall)
  • ES6803-4M-COLD Wallgate Single Piezo and Cable for Basin Assembly with 4 Metre (To Suit Plate)
  • ES6803-4M-CWC Wallgate Single Piezo and Cable for Pan Assembly 4 Metre (To Suit Plate)
  • WVPS400-AUS Wallgate Water Valve Pack Shower Complete with 1x 8lpm Solenoid 4m Cables

Alternative Product Options

  • 123.20.13.90 Wallgate WDC100-NX Electronic Water Controller, 1 Room / 4 Outlets, Programmable

Superseding Products

  • WDC200 Wallgate Electronic Water Controller 2 Rooms / 8 Outlets Programmable

This product is compatible with

  • 123.01.13.40 Wallgate Ligature Resistant S/Surface Wall Basin with Integ Outlet & 1 IR Sensor - Rear Fixed
  • 123.01.11.40 Wallgate Ligature Resistant S/Surface Wall Basin with Integ Outlet & 1 Piezo - Rear Fixed
  • 123.01.14.40 Wallgate Ligature Resistant S/Surface Wall Basin with Integ Outlet & 2 IR Sensors - Rear Fixed
  • 123.01.12.40 Wallgate Ligature Resistant S/Surface Wall Basin with Integ Outlet & 2 Piezos - Rear Fixed
  • CIST19-ELEC Wallgate Electronic Activated Concealed Slimline Cistern 3.0L & 4.5L

Environmental Sustainability

We are ISO 14001 certified and take sustainability seriously. Our products are environmentally responsible designed to be healthier for users, save water and/or energy, and minimise carbon footprint. Our target is to reduce our carbon footprint by 25%, and the use of non-recyclable/non-compostable materials across the company (e.g. plastics) by 50%.

Warranty

Galvin Engineering products are covered under our Manufacturer's Warranty. Galvin Engineering products must be installed in accordance with the installation instructions and in accordance with AS 3500 and NCC Volume Three, relevant Australian Standards and local authorities applicable to product being installed. Water and electrical supply conditions must also comply to the applicable national and/or state standards, failing to comply with these provisions may void the product warranty and affect performance of the product.

Please visit www.galvinengineering.com.au to view the full warranty, our Installation Compliance and Maintenance & Cleaning information as well as any other additional information.

While all reasonable care has been taken in compiling the information in this document, the designs, dimensions and products shown are indicative only and should not be relied upon without our prior approval. Due to our policy of continuous development, we reserve the right to alter any details of specifications or products without notice. All information, drawings, technical specifications and product designs remain the property of Galvin Engineering Pty Ltd.