Skip to main content

Specification Data Sheet

The Wallgate concealed services solid surface mechanical basin combines maximum ligature resistant performance with flexible mechanical control configuration for high-security mental health, forensic and custodial environments. The basin incorporates an integrated outlet that eliminates a ligature point or vandalism target, while the one-piece moulded construction delivers exceptional durability in demanding applications. Water delivery is controlled via separately specified ligature resistant Galvin tapware such as point-of-use TMV mixers or wall top assemblies for a safe, normalised bathroom environment. The polycarbonate solid surface finish and warm-touch composite material provide a more refined user experience compared to traditional institutional stainless-steel fixtures.


Why Specify

  • Ligature resistant – one-piece moulded construction with concealed outlet and services, designed for paired use with ligature-resistant Galvin tapware (sold separately)
  • Vandal resistant – polycarbonate solid surface composite, non-distorting and non-scratch
  • Shatterproof – solid surface absorbs impact without fracturing, removing shard and weapon risk
  • Normalised aesthetic – domestic basin profile and finish, designed to mimic a home-like environment rather than a custodial or clinical one, supporting patient dignity and recovery in mental health and aged care settings
  • Warm to touch – unlike stainless steel, solid surface composite does not retain the cold of the bathroom environment, which matters in cooler climates, unheated ensuites, and for users with tactile or sensory sensitivities
  • Also available with electronic piezo (single or dual), or infrared sensor (single or dual) activation (see Alternative Product Options)
  • Concealed services – water and waste run through the wall, no exposed pipework, no isolation valves visible
  • Refurbishable in situ – surface can be sanded and re-polished on the wall, no replacement required
  • Rear-fixed installation – for solid wall installations

       Read more about Solid Surface


Applications

Specified across the highest-acuity high-risk environments where ligature resistance, vandal resistance and water management are all required:

  • Mental health acute and forensic inpatient bedrooms – including AusHFG B.1034 Adult Acute and the AusHFG mental health planning units
  • Custodial and corrections facilities – single-occupancy cells, holding rooms, observation rooms
  • NDIS SDA Robust standard bathrooms in the higher-acuity tier
  • Secure healthcare wards and behavioural assessment areas in acute hospitals

Installation

  • Supplied as a single moulded unit with integrated outlet.
  • Rear-fixed installation only – for front-fixed configurations see the 123.02 series (with shelf) or WHB-200.
  • Specifiers must include an appropriate ligature resistant activation on the project specification – these are sold separately.
  • Not compatible with ligature resistant basin waste grille (821351)
  • Installation must be in accordance with the supplied installation instructions, AS/NZS 3500 and NCC 2022 Volume Three.

Technical Information

  • WaterMark certified: AS 3718 Lic. 023196
  • WELS: 6 Star Rating (4.5L/min)
  • AusHFG code: HYBA-141 - BASIN: type C, handwashing
  • Nominal Flow Rate (LPM): 4.1
  • Inlet: G1/2 Female
  • Dimensions: 400mm (W) x 300mm (L) x 256mm (D)
  • Waste: Rear 32mm Pipe with 40mm Adaptor
  • Material/Finish: Highly Polished High Grade Solid Surface

Optional Extras

  • 100.81.20.20 CliniMix® CMV2 Wall Mtd Handsfree POU, Proximity, CP Face Plate & Ligature Resistant Outlet
  • 100.81.10.20 CliniMix® CMV2 Wall Mtd Handsfree POU, Wave On/Off, CP Face Plate & Ligature Resistant Outlet
  • 100.50.76.02 CliniMix® Lead Safe™ Ligature Resistant Thermo Prog Shower Mixer & GalvinCare® Handle H&C - Elect
  • 100.50.75.02 CliniMix® Lead Safe™ Ligature Resistant Thermo Progressive Basin/Shower Mixer & GalvinCare® Handle H&C
  • 100.50.75.01 CliniMix® Lead Safe™ Ligature Resistant Thermo Progressive Basin/Shower Mixer & GalvinCare® Handle W&C

Alternative Product Options

  • 123.01.11.40 Wallgate Ligature Resistant Solid Surface Electronic Wall Basin with Integrated Outlet & 1 Piezo, Rear Fixed
  • 123.01.12.40 Wallgate Ligature Resistant Solid Surface Electronic Wall Basin with Integrated Outlet & 2 Piezos, Rear Fixed
  • 123.01.13.40 Wallgate Ligature Resistant Solid Surface Electronic Wall Basin with Integrated Outlet & 1 IR Sensor, Rear Fixed
  • 123.01.14.40 Wallgate Ligature Resistant Solid Surface Electronic Wall Basin with Integrated Outlet & 2 IR Sensors, Rear Fixed
  • 123.02.00.40 Wallgate Ligature Resistant Solid Surface Wall Basin with Integrated Outlet & LH Shelf, Front Fixed
  • 123.02.10.40 Wallgate Ligature Resistant Solid Surface Wall Basin with Integrated Outlet & RH Shelf, Front Fixed

Superseding Products

  • WHB-201W-NB-AUS Wallgate Ligature Resistant S/Surface Basin with Single Outlet 0TH

Environmental Sustainability

We are ISO 14001 certified and take sustainability seriously. Our products are environmentally responsible designed to be healthier for users, save water and/or energy, and minimise carbon footprint. Our target is to reduce our carbon footprint by 25%, and the use of non-recyclable/non-compostable materials across the company (e.g. plastics) by 50%.

Warranty

Galvin Engineering products are covered under our Manufacturer's Warranty. Galvin Engineering products must be installed in accordance with the installation instructions and in accordance with AS 3500 and NCC Volume Three, relevant Australian Standards and local authorities applicable to product being installed. Water and electrical supply conditions must also comply to the applicable national and/or state standards, failing to comply with these provisions may void the product warranty and affect performance of the product.

Please visit www.galvinengineering.com.au to view the full warranty, our Installation Compliance and Maintenance & Cleaning information as well as any other additional information.

While all reasonable care has been taken in compiling the information in this document, the designs, dimensions and products shown are indicative only and should not be relied upon without our prior approval. Due to our policy of continuous development, we reserve the right to alter any details of specifications or products without notice. All information, drawings, technical specifications and product designs remain the property of Galvin Engineering Pty Ltd.

Galvin Engineering offers a range of ligature resistant, anti-ligature, vandal resistant, and anti-vandal products designed to reduce the risk of self-harm, suicide, or vandalism, but we cannot offer any guarantee that these events will not take place. Therefore, it is important to understand that installation of these products will not eliminate all risks.

When we use the terms ligature resistant and/or anti-ligature about our products, it means that we have designed and tested these products to reduce the risk of that product being used as a ligature attachment point. They will not protect or prevent injury when the risks were unknown to us at the time of the design of the products. They are not a replacement for professionals who are trained in the proper evaluation, management, and supervision of persons at risk of self-harm or suicide.

When we use the terms vandal resistant and/or anti-vandal about our products, it means that we have designed and tested these products to reduce the risk of that product being vandalised. They will not protect or prevent damage when the risks were unknown to us at the time of the design of the products.

Galvin Engineering recommends that designers, installers, facility managers, and anyone intending to rely on or use any products displayed in our literature or on our website, satisfy themselves about the suitability of the products for their intended use in the building design, and ensure they are being installed, used, and maintained in accordance with our instructions. Facility managers, clinicians, and carers need to ensure that reasonable steps are taken to reduce the accessibility of unnecessary ligatures to at-risk patients, confirm that adequate risk mitigation controls are in place, and make sure that applicable health, safety and patient care standards are being met.

Galvin Engineering makes no express or implied warranties regarding the ability of the product to prevent death or injury, to resist all ligature attachment, or to prevent vandalism. No responsibility is assumed by Galvin Engineering for any incidental or consequential damages resulting from the use of any products sold by Galvin Engineering. To the fullest extent permitted by law, Galvin Engineering excludes all liability for damage or injury to any person, damage to any property, and any indirect consequential claims, loss or damage.